Operating systems

As of STEP 7 V5.4 SP3, the MS Windows Vista 32 Business and Ultimate operating systems are also supported.

SIMATIC Manager

·         There are two formats available for displaying the date and the time. You can select a display in the respective STEP 7 national language and or in ISO 8601 standard format. To make this setting, go to the SIMATIC Manager, open the "Customize" dialog box and select the "Date and Time" tab.

·         You can have module times displayed in the local time for your programming device (PG)/PC. To make this setting, go to the SIMATIC Manager, open the "Customize" dialog box and select the "Date and Time" tab.

·         You have the option of restricting access to projects and libraries by assigning a password to them. In order to do this, you must have installed SIMATIC Logon V1.3 SP1 and SIMATIC Logon V1.4 SP1 under MS Windows Vista (as of now referred to as SIMATIC Logon) (see What You Should Know About Access Protection).

·         After setting up access protection for projects and libraries, you have the option of keeping a change log that records online actions such as "Download", "Operating Mode Changes", and "Reset". In order to do this, you must have installed SIMATIC Logon V1.3 SP1 and SIMATIC Logon V1.4 SP1 under MS Windows Vista (as of now referred to as SIMATIC Logon) (see What You Should Know About Access Protection).

·         As of V5.4 SP3, the supplied PKZip V8.6 CLI archiving program is provided as a standard component for archiving and retrieving projects and library. Under MS Windows Vista, ARJ.exe,  previously supplied on the CD is no longer installed for this operating system due to lacking compatibility. PKZip V8.6 CLI supports the ZIP format that is standard in STEP 7 and which can also open some other archive formats, such as ARJ. If the previously used archive format is no longer available under MS Windows Vista, or if it is not supported by PKZip, retrieve your projects on the platform you have used to date and archive them again with PKZip V8.6 CLI.

0 comments:

Post a Comment

Labels

Actuator Sensor-interface Address Negative Edge Detection Address Positive Edge Detection ADDRESSING ANALOG INPUTS ANALOG OUTPUTS AND Logic Operation AS-i AS-i configuration Assign Authorizations Automation License Manager BASICS Bit Bit Configuration Bit Logic Instructions Block By-passing CiR CiR Modules CiR Objects communication COMPARISON Components Configuration Configuring Connections Conversion Converting Counter CP 343-2 P CP 443-5 Ext CPU CPU 412-1 CPU 412-2 DP CPU 412-2 PCI CPU 414-2 DP CPU 414-3 DP CPU 414-4 H CPU 416-2 DP CPU 416-2 PCI CPU 416-3 DP CPU 416F-2 CPU 417-4 CPU 417-4 H Data Block DI/DO MODULES Diagnosing Diagnosis DIGITAL INPUTS DIGITAL OUTPUTS Downloading DP master English Mnemonics ET 200M Exclusive OR Logic Operation Extended pulse timer fail-safe modules fault FBD Floating- Point Floating-Point Math FUNCTION MODULES German Mnemonics Hardware hmi Input Insert Binary Input install Instructions Integer Math INTERFACE MODULES Jump License License Keys Load Memory Master Control Relay Memory Areas Memory Reset Midline Output Modifying MODULES monitoring variables Move NEG Negate Binary Input Negative RLO Edge Detection Networks Off-delay timer On-delay timer Operating systems OR Logic Operation Output PID Control PLC POS position decoder Positive RLO Edge Detection PROFIBUS Program Control programm Programming Pulse timer RELAY OUTPUTS Remote Reset Output Reset_Set Flip Flop Retentive on-delay timer Rotate RS S5 File S7 Communications S7-300 S7-400 SAVE Save RLO to BR Memory SCADA Set Output Set_Reset Flip Flop Shift siemens SIMATIC SIMATIC Manager Slaves Software SR STATEMENT Status Bit STEP 7 stop mode Time Base Time Value Timer Timer Cell TRAINING MODULE Units Upgrading UPLOADING WinLC RTX Word Logic Work Memory XOR