Configuring and Diagnosing Hardware

·         The "Information and Maintenance" process is supported in order to be able to read identification data from or write identification data to modules. This function is also available in the SIMATIC Manager (see Identification & Maintenance (I&M)).

·         Identification data can also be written to PROFIBUS DP interface modules during redundant mode (by means of "Accessible Nodes"). The interface module must support this function.

·         As of V5.4 SP1, you can also download identification data over PROFINET lO (see Entering or Changing M Data in HW Config).

·         CAx data can be imported and exported. In this way, data can be exchanged between STEP 7 and CAD systems or CAE engineering systems (see Exporting and Importing CAx Data)

·         The firmware for PROFIBUS DP interface modules can also be updated during redundant mode, as long as such a module will support this process. Each of the redundantly used interface modules can now send the updated firmware through the active backplane bus to the other, redundant interface module.

·         The "Software Redundancy" function now allows PA links with subordinate PA slaves to be copied and redundantly inserted (see Configuring SW Redundancy)

·         Applications for editing objects in HW Config can now be started with the Edit > Open Object menu command (see Opening Objects in HW Config).

·         You can configure a watchdog time for PROFINET IO devices (see Configuring the Watchdog Time)

·         You can have module times displayed in the local time of your programming device (PG)/PC.

·         As of V5.4 SP1, you can download language-specific information to CPUs to allow you to read information online with a Web browser in the required language (see Configuring the CPU for Web Access).

·         As of V5.4 SP2, you call tools external to STEP 7 from HW Config to configure distributed devices (see Integrating Tools for Configuration of Distributed Devices (TCI; Tool Calling Interface)).

·         As of V5.4 SP2, the PROFINET Topology Editor is included in STEP 7. It contains a graphical and tabular view, and online views with diagnostic information.

·         As of V5.4 SP2, you can configure additional PROFINET IO devices with IRT (S7-CPU, ET200, ScalanceX).

·         As of V5.4 SP3 you can assign asset IDs to modules within the framework of asset management. These asset IDs are then available to the TIA Maintenance Station (see Assigning Asset IDs).

Additional PROFINET IO functions are available with SIMOTION/Scout:

·         As of V5.4 SP2, you can configure "direct data access" to F modules (SINAMICS_Integrated) for special SIMOTION CPUs / D4x5 controller as lower-level I slaves (see Direct Data Access to a Module in the Lower-level I Slave). This can only be done within the context of SIMOTION/Scout!

·         As of V5.4 SP2, you can configure intelligent IO devices in IRT mode (see What You Should Know about Configuring Intelligent IO Devices). This can only be done within the context of SIMOTION/Scout!

·         As of V5.4 SP2, you can set update times for PROFINET IO devices in IRT mode as can be done for PROFINET IO devices of the RT classes (see Update Times for Cyclic Data Exchange). This can only be done within the context of SIMOTION/Scout!

·         As of V5.4 SP2, you can configure redundant sync masters for a PROFINET IO configuration with devices in IRT mode (see Configuring Redundant Sync Masters). This can only be done within the context of SIMOTION/Scout!

0 comments:

Post a Comment

Labels

Actuator Sensor-interface Address Negative Edge Detection Address Positive Edge Detection ADDRESSING ANALOG INPUTS ANALOG OUTPUTS AND Logic Operation AS-i AS-i configuration Assign Authorizations Automation License Manager BASICS Bit Bit Configuration Bit Logic Instructions Block By-passing CiR CiR Modules CiR Objects communication COMPARISON Components Configuration Configuring Connections Conversion Converting Counter CP 343-2 P CP 443-5 Ext CPU CPU 412-1 CPU 412-2 DP CPU 412-2 PCI CPU 414-2 DP CPU 414-3 DP CPU 414-4 H CPU 416-2 DP CPU 416-2 PCI CPU 416-3 DP CPU 416F-2 CPU 417-4 CPU 417-4 H Data Block DI/DO MODULES Diagnosing Diagnosis DIGITAL INPUTS DIGITAL OUTPUTS Downloading DP master English Mnemonics ET 200M Exclusive OR Logic Operation Extended pulse timer fail-safe modules fault FBD Floating- Point Floating-Point Math FUNCTION MODULES German Mnemonics Hardware hmi Input Insert Binary Input install Instructions Integer Math INTERFACE MODULES Jump License License Keys Load Memory Master Control Relay Memory Areas Memory Reset Midline Output Modifying MODULES monitoring variables Move NEG Negate Binary Input Negative RLO Edge Detection Networks Off-delay timer On-delay timer Operating systems OR Logic Operation Output PID Control PLC POS position decoder Positive RLO Edge Detection PROFIBUS Program Control programm Programming Pulse timer RELAY OUTPUTS Remote Reset Output Reset_Set Flip Flop Retentive on-delay timer Rotate RS S5 File S7 Communications S7-300 S7-400 SAVE Save RLO to BR Memory SCADA Set Output Set_Reset Flip Flop Shift siemens SIMATIC SIMATIC Manager Slaves Software SR STATEMENT Status Bit STEP 7 stop mode Time Base Time Value Timer Timer Cell TRAINING MODULE Units Upgrading UPLOADING WinLC RTX Word Logic Work Memory XOR