Configuring Networks and Connections

·         PROFINET IO with IRT Communication (Isochronous Realtime) is supported. This means that short and equal-length bus-cycle times can also be configured for PROFINET IO (see Introduction: Isochronous Realtime Ethernet).

·         There is improved handling when inserting copied IO devices into another station. If the IP addresses are already assigned, you can specify the action to be taken upon insertion (retain addresses or assign new ones).

·         In a manner similar to that for PROFIBUS DP slaves, you can now set the watchdog time for PROFINET IO devices: as an object property of the IO device in the "IO Cycle" tab.

·         When using optical components for PROFIBUS DP: when configuring with an optical ring, you can specify the optical link modules (OLMs) to be used. This makes calculation of bus parameters more exact. In addition, it means that the bus cycle time can be shortened when higher-performance components are being used.

Standard Libraries

·         The standard library "Communication Blocks" has been expanded with the blocks FB 67 and FB 68 for open TCP/IP communication.

·         The standard library "Communication Blocks" has been expanded with the blocks FB 20, FB 21, FB 22 and FB 23 for cyclic accessing of user data in accordance with the German PROFIBUS User Organization [PROFIBUS Nutzerorganisation e.V. (PNO)].

·         In addition to the existing redundancy library "Redundant IO (V1)", there is the new block library "Redundant IO CGP" (channel granular peripheral devices). It supports redundancy for single module channels. You can find further information in the context-sensitive block help or the STEP 7 readme file. A current list of supported modules is available under the FAQs here: http://support.automation.siemens.com/.

·         As of V5.4 SP2, the system functions for SFC 109 "PROTECT“ have been expanded for activation of write-protection.

Report System Error

·         As of STEP 7 V5.4, a data block (DB 125) for PROFIBUS is supported. This data block can be used to output diagnostic events on an HMI device.

·         As of V5.4 SP1, you can export messages and error texts after you have generated them.

·         As of V5.4 SP1, you can use the unique name of the station from the S7 project in the message information that you configure in the "Messages" tab.

·         As of V5.4 SP2, you can specify values for any type of reporting component, which can be used in the generation of messages.

·         As of V5.4 SP2, the support for AS I links has been expanded.

Diagnostics

·         As of STEP 7 V5.4 SP1, maintenance information is displayed for certain PROFINET IO components (see Hardware Diagnostics and Troubleshooting).

·         As of STEP 7 V5.4 SP1, the module information functions for PROFINET IO interfaces and their ports on CPUs with an integrated Ethernet interface have been expanded by the "Communication Diagnostics" tab (see Module Information Functions) when the module supports this function.

·         As of V5.4 SP2, the functions of the module information for diagnostic repeaters as been expanded with the "DP Cycle Time“ tab.

·         As of V5.4 SP2, the functions of the module information for PROFINET IO devices has been expanded with the "Identification“ tab.

·         As of V5.4 SP2, the "Network Connection“ tab of the module information is now also displayed for PROFINET IO ports.

·         As of V5.4 SP2, the "Statistics“ tab of the module information now has two views.

·         As of V5.4 SP2, the "Module Information“ dialog box has been expanded with the current protection level of your CPU.

0 comments:

Post a Comment

Labels

Actuator Sensor-interface Address Negative Edge Detection Address Positive Edge Detection ADDRESSING ANALOG INPUTS ANALOG OUTPUTS AND Logic Operation AS-i AS-i configuration Assign Authorizations Automation License Manager BASICS Bit Bit Configuration Bit Logic Instructions Block By-passing CiR CiR Modules CiR Objects communication COMPARISON Components Configuration Configuring Connections Conversion Converting Counter CP 343-2 P CP 443-5 Ext CPU CPU 412-1 CPU 412-2 DP CPU 412-2 PCI CPU 414-2 DP CPU 414-3 DP CPU 414-4 H CPU 416-2 DP CPU 416-2 PCI CPU 416-3 DP CPU 416F-2 CPU 417-4 CPU 417-4 H Data Block DI/DO MODULES Diagnosing Diagnosis DIGITAL INPUTS DIGITAL OUTPUTS Downloading DP master English Mnemonics ET 200M Exclusive OR Logic Operation Extended pulse timer fail-safe modules fault FBD Floating- Point Floating-Point Math FUNCTION MODULES German Mnemonics Hardware hmi Input Insert Binary Input install Instructions Integer Math INTERFACE MODULES Jump License License Keys Load Memory Master Control Relay Memory Areas Memory Reset Midline Output Modifying MODULES monitoring variables Move NEG Negate Binary Input Negative RLO Edge Detection Networks Off-delay timer On-delay timer Operating systems OR Logic Operation Output PID Control PLC POS position decoder Positive RLO Edge Detection PROFIBUS Program Control programm Programming Pulse timer RELAY OUTPUTS Remote Reset Output Reset_Set Flip Flop Retentive on-delay timer Rotate RS S5 File S7 Communications S7-300 S7-400 SAVE Save RLO to BR Memory SCADA Set Output Set_Reset Flip Flop Shift siemens SIMATIC SIMATIC Manager Slaves Software SR STATEMENT Status Bit STEP 7 stop mode Time Base Time Value Timer Timer Cell TRAINING MODULE Units Upgrading UPLOADING WinLC RTX Word Logic Work Memory XOR