What is AS-i?
 A simple network for actuators and sensors
 Connects input / output devices to a PLC or PC
 Connects I/O devices to a two-wire flat cable
 Eliminates multiple terminations
 Easily replaces point-to-point wiring systems
 A complete networking solution

Point-to-Point Wiring vs. AS-i Networking
Point-to-Point Wiring
 Large wire bundles take up valuable space
 Installation time is considerable
 Troubleshooting is complex
Actuator Sensor-interface Networking
 Completely eliminates wire bundles
 Plug-and-play wiring supports all topologies
 Eliminates junction boxes and reduces the size of the control cabinet
Why Choose AS-i…
 A simple 2-wire flat cable
 Extremely fast system
 Insulation displacement
 Flexible topology
 Cost effective
 Best fit
 Modular system
An Overview of AS-i System Components
Two methods to connect AS-i to your existing control platform:
Method 1: Backplane Master Connection
 Fits in a standard card slot in a plc rack
 Plugs into backplane
 Replaces traditional I/O cards
 I/Os are mapped directly to I/O tables
 Programmed via the standard plc software

Method 2: Fieldbus Gateway Connection
 Connects to higher-level fieldbus systems
 Gateway becomes a single node on the fieldbus network
 Reduces the price per point for connecting sensors and actuators

After selecting connection method, choose an AS-i Power Supply
 An integral and necessary part of an AS-i system
 Provides power to all input devices and modules
 Couples the master data and 24 VDC power for transmission over the yellow flat cable
Field Input and Output Modules
Connects the AS-i master and periphery equipment Compact Modules
 Designed for harsh environments
 Rated IP67 for washdown environments
 M12 connectors for simple plug-and-play wiring Classic modules
 DIN rail mountable
 For areas with limited mounting space
 Rated IP67
 Equipment such as pushbuttons and motor starters can be connected to cabinet modules Cabinet Modules
 Rated IP20
 I/O modules may be daisy-chained together inside the enclosure
 DIN rail mounting

Intelligent System Solutions
Pneumatic Modules
 The airbox is a single AS-i node with up to four inputs and two integrated pneumatic outputs
 Stainless steel options for heavy washdown environments
 Ideal solution for distributed valve applications
Quarter-Turn Valve Feedback
 One cable can connect 31 quarter-turn valve feedback devices and 31 solenoid valves
 IND sensor and integrated output for a solenoid valve are networked with AS-i

The AS-i Networking System Complements Existing Bus Systems
 Dramatic cost savings for actuators and sensors
 Reduced engineering design time
 Eliminates trunk and drop line calculations
 Communication is transparent
 No terminating resistors
 No technical descriptive data files
• On Devicenet: EDS files
• On Profibus: GDS files
Benefits to Equipment Builders
 Reduces engineering design time
 Reduces BOM costs
 Easy commissioning for new machines
 Easy troubleshooting
 No additional software
Benefits for End-Users
Reduced maintenance costs
Easy troubleshooting
Easy expansion of existing systems in-house
Free training seminars by ifm efector
ifm efector introduces Controller-e
 High-speed, integrated AS-i master and PLC
 Can be used as a gateway to higher-level bus
systems and as a stand-alone PLC
 Supports all 2.1 AS-i specifications
 Integrated backlit LCD display with status LEDs
 1 MB of total memory with 128 Kwords
program memory
 Connects 124 AS-i nodes for a total 868 I/O points
 Standard IEC 61131-3 programming



0 comments:

Post a Comment

Labels

Actuator Sensor-interface Address Negative Edge Detection Address Positive Edge Detection ADDRESSING ANALOG INPUTS ANALOG OUTPUTS AND Logic Operation AS-i AS-i configuration Assign Authorizations Automation License Manager BASICS Bit Bit Configuration Bit Logic Instructions Block By-passing CiR CiR Modules CiR Objects communication COMPARISON Components Configuration Configuring Connections Conversion Converting Counter CP 343-2 P CP 443-5 Ext CPU CPU 412-1 CPU 412-2 DP CPU 412-2 PCI CPU 414-2 DP CPU 414-3 DP CPU 414-4 H CPU 416-2 DP CPU 416-2 PCI CPU 416-3 DP CPU 416F-2 CPU 417-4 CPU 417-4 H Data Block DI/DO MODULES Diagnosing Diagnosis DIGITAL INPUTS DIGITAL OUTPUTS Downloading DP master English Mnemonics ET 200M Exclusive OR Logic Operation Extended pulse timer fail-safe modules fault FBD Floating- Point Floating-Point Math FUNCTION MODULES German Mnemonics Hardware hmi Input Insert Binary Input install Instructions Integer Math INTERFACE MODULES Jump License License Keys Load Memory Master Control Relay Memory Areas Memory Reset Midline Output Modifying MODULES monitoring variables Move NEG Negate Binary Input Negative RLO Edge Detection Networks Off-delay timer On-delay timer Operating systems OR Logic Operation Output PID Control PLC POS position decoder Positive RLO Edge Detection PROFIBUS Program Control programm Programming Pulse timer RELAY OUTPUTS Remote Reset Output Reset_Set Flip Flop Retentive on-delay timer Rotate RS S5 File S7 Communications S7-300 S7-400 SAVE Save RLO to BR Memory SCADA Set Output Set_Reset Flip Flop Shift siemens SIMATIC SIMATIC Manager Slaves Software SR STATEMENT Status Bit STEP 7 stop mode Time Base Time Value Timer Timer Cell TRAINING MODULE Units Upgrading UPLOADING WinLC RTX Word Logic Work Memory XOR